Item Number:

T70 DFS

 

Product Description:

 

 

Fabric using .025" dia. vinyl-coated 1000 den. polyester core yarns in the warp and fill.

Attribute

ASTM

Warp

 Fill

Construction, end/inch

D3775-96

13.0 .5

  11.0 .5

Weight, oz/yd2

D3776-96

 —

Tensile Strength (grab), lbf

D5034-95

221.4

 213.3

Tensile Strength (strip), lbf

D5035-95

194.9

 153.8

Tear Strength, (Trapezodial), lbf

D1117-97

65.4

 54.0

Ball Burst, lbf

D3787-89

335

Bursting Strength, psi

D3786-89

433

Elongation, %

D5035-95

24.3

 21.6

Abrasion Resistance

D3884-92

 

No exposure of core yarn

(CS10/500 cycles/ with no added weight)

 

 

 

Flammability Rating

 

 

CS-191-53 & CA 117E

Weatherability, 1200 hours

G53-96

 

No discoloration 

Mildew Resistance

G21-96

 

No growth

 

 

 

 

** The above results are a representative of real data from single test samples.

   Presently no specification is incorporated.

 

 

Quad-X Reinforced 1” Aluminum Pole

Life Saver Pool Fence uses Quad-X Reinforced 6063T6 1” Aluminum Poles spaced no more than 36” apart. Mesh is secured to the pole via an aluminum cove molding using roundhead screws spaced no greater than 6”.

The temper rating of T6 scores the highest tensile strength (30 ksi) within the 6063 alloy classification.

On July 14th, 2003, Life Saver Pool Fence Systems, Inc. contracted Nutting Engineers of Florida, Inc., an ASTM standards testing lab established in 1967, to test the pole strength as per the Florida Building Code section 424.2.17.1.15.

At the time of testing, a lateral force was applied to a single pole at a measurement of 36” from the surface of the deck. In the test, the resistance to lateral pressure was found to exceed 70 lbs. of pressure before failure on any single pole in a free standing installation, thus exceeding the 52 lbs. of horizontal force prescribed by the Florida Building Code section 424.2.17.1.15 Paragraph 1.

ASTM F-2286-05

On January 10, 2006, Life Saver Pool Fence was found to meet and exceed all requirements for ASTM Standard F-2286-05.